Emergency Stop

An emergency stop is the red, latching control on a yellow background that when pressed, overrides everything else and brings a machine to a safe stop in an emergency.

Design rules come from EN ISO 13850 and EN 60204-1: it must latch when struck, need a deliberate manual reset, and resetting must never restart the machine on its own. Under PUWER Regulation 16 e-stops are provided where appropriate, as the backup for the moment other safeguards have failed.

Other Terms

Guard Locking

Guard locking keeps an interlocked guard locked shut until the machine inside has come to a complete stop and the guard has been released by a control device.

Read definition ›