Plain-English definitions of the standards, regulations and safeguarding concepts used in machinery safety. Use this glossary to decode the jargon you meet in audits, risk assessments and compliance documents. Each term links to a full definition, with other terms and further reading alongside it.
Approved Body
An approved body is the Great Britain counterpart of an EU notified body, providing third-party conformity assessment on the UKCA route.
Authorised Representative
An authorised representative is an EU-based person or company acting on behalf of a non-EU manufacturer to ensure a product meets EU requirements.
Automatic Disconnection of Supply
Automatic disconnection of supply is the protective measure that removes power to a faulty circuit within a required time to prevent electric shock.
CE Marking
CE marking is a manufacturer’s own declaration that machinery meets the EU’s essential health and safety requirements.
Cobot
A collaborative robot, or cobot, is an industrial robot designed to work safely alongside people, using force and load monitoring to detect impacts and maintain safe operation.
Competent Person
A competent person is someone with the practical and theoretical knowledge and experience needed to carry out a specific safety-critical task, such as a LOLER thorough examination.
Conformity Assessment
Conformity assessment is the process a manufacturer follows to demonstrate machinery meets the law before placing it on the market.
Controlled Stop
A controlled stop, or Stop Category 1, keeps power on to decelerate a machine before removing it, avoiding the hazards a straight removal of power can introduce.
COSHH
COSHH is the UK regulation governing the control of substances hazardous to health, covering everything from chemical storage to housekeeping in an audit.
Declaration of Conformity
A Declaration of Conformity is the signed legal statement that a machine complies with every directive and regulation that applies to it.
Declaration of Incorporation
A Declaration of Incorporation is the document issued with partly completed machinery in place of a Declaration of Conformity.
Designated Standards
Designated standards are Great Britain’s equivalent of harmonised standards, carrying a presumption of conformity with UK product legislation.
Due Diligence
Due diligence is the process an end user follows to satisfy themselves that machinery is genuinely CE/UKCA compliant, starting with checking the Declaration of Conformity.
Duty Holder
A duty holder is the person or organisation legally responsible for ensuring compliance with a given piece of health and safety legislation.
Earth Fault Loop Impedance
Earth fault loop impedance is the total impedance of the fault current path, measured to confirm that a protective device will disconnect the supply fast enough in a fault condition.
Economic Operator
An economic operator is any party in the supply chain, manufacturer, authorised representative, importer or fulfilment service provider, on whom compliance obligations can fall.
EMC Directive
The EMC Directive 2014/30/EU sets the rules for how equipment must be designed to limit the electromagnetic disturbance it emits and to withstand the disturbance it receives.
Emergency Stop
An emergency stop is the red, latching control on a yellow background that when pressed, overrides everything else and brings a machine to a safe stop in an emergency.
EN 60204-1
EN 60204-1 is the standard covering the electrical equipment of machines: supply isolation, control circuits, e-stop functions and verification testing.
EN IEC 62061
EN IEC 62061 is a machinery standard for safety-related control systems; it grades each safety function by Safety Integrity Level.
EN ISO 10218
EN ISO 10218 is the standard for industrial robot safety, deriving the Performance Level of a robot’s safety functions from a risk assessment against EN ISO 12100.
EN ISO 12100
EN ISO 12100 is the foundation standard for machinery risk assessment; every machine safety decision traces back to its method.
EN ISO 13849-1
EN ISO 13849-1 is the standard for designing and validating the safety-related parts of machine control systems; the yardstick is Performance Level.
EN ISO 13850
EN ISO 13850 is the standard that sets the design principles for emergency stop functions: actuation, reset, priority and span of control.
EN ISO 13855
EN ISO 13855 sets where to position light curtains, scanners, mats and other protective devices, using human approach speed and the machine’s stopping time.
EN ISO 13857
EN ISO 13857 defines the safety distances that stop people reaching hazard zones over, under, around or through guard openings with their upper or lower limbs.
EN ISO 7010
EN ISO 7010 is the standard that fixes the shapes, colours and pictograms for safety signs, so a warning means the same thing on any site.
Essential Health and Safety Requirements (EHSRs)
Essential health and safety requirements are the legally binding requirements machinery must meet before it can be placed on the UK or EU market.
EU Machinery Regulation 2023/1230
Regulation (EU) 2023/1230 replaces the Machinery Directive on 20 January 2027 and adds requirements on software, AI safety functions and cybersecurity.
EU-Type Examination
EU-type examination is a conformity assessment route requiring a notified body to examine and certify a machine design before it can be placed on the market.
Fixed Guard
A fixed guard is a physical barrier, fastened in place with no moving parts of its own, that keeps people away from a machine’s hazardous parts.
Functional Safety
Functional safety is the part of a machine’s safety that depends on its control system working correctly, from sensor through logic to actuator.
Guard Locking
Guard locking keeps an interlocked guard locked shut until the machine inside has come to a complete stop and the guard has been released by a control device.
Harmonised Standards
Harmonised standards are European standards with legal weight: follow them and your machinery is presumed to meet the essential requirements.
Health and Safety at Work Act 1974
Health and Safety at Work Act 1974 is the foundational UK law setting out the general duties employers and employees owe each other for health and safety at work.
Health and Safety Executive
The Health and Safety Executive is the UK regulator responsible for enforcing workplace health and safety laws, providing guidance, and inspecting the workplace.
Hierarchy of Controls
The hierarchy of controls ranks risk reduction measures from most to least effective: eliminate, substitute, isolate, engineer, administer, and only then rely on PPE.
Insulation Resistance Test
The insulation resistance test applies a DC test voltage across a machine’s electrical installation to confirm the insulation is intact and not at risk of breakdown.
Intended Use
Intended use is what a machine was designed and assessed to do, as stated by its manufacturer in the instructions and technical documentation.
Interlocked Guard
An interlocked guard is a movable guard wired to the machine’s safety controls: open it and the hazardous movement stops until the guard is closed again and the machine restarted.
Interlocking Device
An interlocking device links a guard to the machine’s controls so the machine cannot run while the guard is open, and will stop if the guard is opened during a hazardous movement.
Isolation
Isolation is the act of disconnecting a machine’s energy sources, electrical, hydraulic, pneumatic or stored, so it cannot operate during maintenance.
Isolator Switch
An isolator switch is a compliant on-off device, correctly coloured and lockable, that lets maintenance teams safely de-energise a machine before servicing.
Lifting Accessory
A lifting accessory is a component, not attached to the lifting machinery, that’s used to attach a load, such as a chain sling, C-hook or lifting beam.
Lifting Beam
A lifting beam is a rigid lifting accessory, sometimes just a plate with a welded lifting eye, that distributes a load across multiple attachment points.
Light Curtain
A light curtain is an optoelectronic device that projects a field of infrared beams in front of a hazard and stops the machine the instant a beam is broken.
Lockout Tagout (LOTO)
Lockout tagout is the procedure of isolating a machine’s energy sources and locking them off so it cannot start while someone is working on it.
LOLER
LOLER, the Lifting Operations and Lifting Equipment Regulations 1998, adds duties for lifting equipment on top of PUWER, which still applies alongside it.
Low Voltage Directive
The Low Voltage Directive 2006/95/EC sets the safety requirements for electrical equipment operating within defined voltage ranges, one of the directives a compliant control panel must meet.
Machinery Directive 2006/42/EC
The Machinery Directive 2006/42/EC is the EU law that has set the design and build rules for machinery since 2009.
Machinery Safety
Machinery safety is the discipline of keeping people from being hurt by the machines they operate and maintain, through design, guarding and safe use.
Machinery Safety Audit
A machinery safety audit checks your machines against PUWER and current standards and ends in a prioritised, risk-rated action plan.
Manual Handling Operations Regulations 1992
Manual Handling Operations Regulations 1992 require employers to avoid hazardous manual handling where reasonably practicable, and to assess and reduce the risk where it can’t be avoided.
Method Statement
A method statement is a document setting out how a task will be carried out safely, referenced during audit preparation alongside risk assessments.
MEWP
A MEWP, or mobile elevating work platform, is powered access equipment, such as a scissor lift or cherry picker, that must satisfy both PUWER suitability and LOLER lifting performance requirements.
Muting
Muting temporarily suspends a safety device, typically so that a pallet can pass through a light curtain without stopping the line.
Notified Body
A notified body is an independent organisation designated by an EU member state to assess higher-risk machinery before it can be CE marked.
Office for Product Safety and Standards
The Office for Product Safety and Standards is the UK government agency responsible for enforcing product safety and standards and protecting consumers from unsafe products.
Original Equipment Manufacturer
An original equipment manufacturer is the company that designs and builds machinery, often relying on specialist compliance support to navigate CE, UKCA and PUWER requirements.
Own-Use Machinery
Own-use machinery is equipment a business designs, builds or modifies for use on its own site; the law treats the business as the manufacturer regardless.
Partly Completed Machinery
Partly completed machinery is equipment, such as a bare industrial robot, that only becomes a working machine once integrated into an installation.
Performance Level (PL)
Performance Level is the five-step scale in EN ISO 13849-1, from PL a up to PL e, for how reliably a safety function performs when called on.
Personal Fall-Arrest System
A personal fall-arrest system is a harness and safety line arrangement that physically catches a climber within a short distance if they fall, far more reliable than a cage alone.
Placing on the Market
Placing on the market is the point at which discrete machinery is first made available in the UK or EU, triggering full legal responsibility for its compliance.
PPE at Work Regulations 1992
The PPE at Work Regulations 1992 require employers to assess health and safety risks, provide suitable PPE free of charge, ensure it’s used correctly, and maintain it properly.
Pressure-Sensitive Mat
A pressure-sensitive mat stops the machine when someone stands on it, a guard for floor areas where beams and fences are impractical.
Principles of Prevention
The principles of prevention are the recognised order of priority for controlling risk, favouring collective controls over protecting individuals.
Producer Compliance Scheme
A Producer Compliance Scheme is an organisation that UK producers of electrical and electronic equipment must join to manage their WEEE recycling and reporting obligations.
Proof Load Testing
Proof load testing applies a load above the rated working load to demonstrate that a lifting accessory or fabrication performs safely under the required conditions.
Putting into Service
Putting into service is the point at which machinery is first used for its intended purpose, distinct from but closely linked to placing it on the market.
PUWER
PUWER, the Provision and Use of Work Equipment Regulations 1998, governs how work equipment is selected, used, maintained and inspected in service within Great Britain.
Reasonably Foreseeable Misuse
Reasonably foreseeable misuse is use of a machine its maker never intended but should have predicted, like bypassing a guard to clear a blockage.
Required Performance Level (PLr)
Required Performance Level is the reliability target a safety function must achieve, set during risk assessment from severity, frequency and avoidability.
Residual Current Device
A residual current device is a protective device that disconnects a circuit when it detects an imbalance in current, tested as part of a machine’s electrical verification.
Residual Risk
Residual risk is the risk left over once all your control measures are in place, and it decides whether a machine is acceptable to run or needs further work.
Respiratory Protective Equipment
Respiratory protective equipment is PPE, disposable or reusable, worn to protect the wearer from airborne contaminants.
Risk Assessment
A risk assessment identifies the hazards around a machine or task, scores likelihood and severity, then sets out controls to bring the risk down.
Risk Reduction
Risk reduction is the process of driving machinery risk down to an acceptable level; design measures come first and PPE comes last.
Safe System of Work
A safe system of work is a formal procedure designed to ensure a task, such as maintenance, can be carried out without exposing anyone to harm.
Safe Working Load
The safe working load is another term for the rated maximum load a piece of lifting equipment can lift, used interchangeably with WLL.
Safeguarding
Safeguarding is the combination of guards and protective devices that keeps people away from a machine’s dangerous parts while it runs.
Safety Component
A safety component is a component placed on the market separately whose failure endangers people, subject to its own conformity assessment under machinery law.
Safety Distance
Safety distance is the minimum gap between a person and a hazard, set so the dangerous parts cannot be reached before the machine stops, or at all.
Safety Function
A safety function is a specific protective job a machine’s control system performs, such as stopping motion the moment a guard is opened.
Safety Integrity Level (SIL)
Safety Integrity Level is the scale EN IEC 62061 uses to grade how reliable a safety function must be, from SIL 1 to SIL 3 on machinery.
Safety Laser Scanner
A safety laser scanner sweeps a laser across an area and slows or stops the machine when someone enters the zones it has been set to monitor.
Safety-Related Control System
A safety-related control system comprises of a chain of components, sensor to logic to actuator, that carries out a machine’s safety functions.
Self-Certification
Self-certification is the conformity route that lets a manufacturer declare compliance without third-party involvement, available for all machinery not explicitly listed in Annex I of the Machinery Regulation.
Span of Control
Span of control describes exactly what an emergency stop will actually bring to a halt, which must be clear to the person pressing it.
Statutory Instrument
A statutory instrument is a form of UK secondary legislation, made under powers granted by an Act of Parliament, that both PUWER and LOLER take the form of.
Stop Category
Stop categories, defined in EN 60204-1, describe how a machine’s stop function deals with power and associated machine movements: cut it at once, brake first, or keep it on.
Supply of Machinery (Safety) Regulations 2008
The Supply of Machinery (Safety) Regulations 2008 are the UK’s implementation of the Machinery Directive and apply to anyone placing machinery on the market or building machinery for their own use.
Technical File
The technical file is the evidence pack behind a CE or UKCA mark: drawings, calculations, the risk assessment, standards applied and test results.
TILEO
TILEO is the industry-recognised methodology for safe manual handling, standing for Task, Individual, Load, Environment and Other.
Trapped Key Interlocking
Trapped key interlocking, or a trap key system, uses a key that must be removed to cut power and then used to open a guard, preventing the machine restarting while…
Two-Hand Control
A two-hand control makes the operator press two separated buttons at the same time to run the machine, keeping both hands away from the dangerous moving parts.
UK(NI) Indication
The UK(NI) indication is a marking that must sit alongside CE marking where a UK notified body has carried out conformity assessment for the Northern Ireland market.
UKCA Marking
UKCA marking is Great Britain’s post-Brexit conformity mark, introduced in 2021 as the domestic equivalent of CE marking.
WEEE Directive
The WEEE Directive 2012/19/EU governs the disposal and recycling of waste electrical and electronic equipment, sharing its scope and exclusions with RoHS.
Work at Height Regulations 2005
Work at Height Regulations 2005 require employers to prevent falls from height wherever possible, and to minimise the distance and consequences where a fall can’t be ruled out.
Working Load Limit
The working load limit is the maximum load a piece of lifting equipment is rated to lift, which the equipment must be marked with and used within.
Can’t find the term you need?
Speak to a Knox Thomas engineer about compliance, risk assessment and safeguarding for your machinery.